Industrial Safety Controls Inc Product
DOLD Multifunctional safety timer with instantaneous contacts UG 6961
Model: DOLD Multifunctional safety timer with instantaneous contacts UG 6961
The multifunctional safety timer UG 6961 provides protection of men and machines by enabling and disabling a safety circuit. This is done by the adjusted time delay function. Simply select 1 out of 5 delay functions with a rotary switch – ready. The adjusted time is safe over the complete setting range. The UG 6961 is available for different safety functions. It has safe delayed and instantaneous contacts.
Product description
The multifunctional safety timer UG 6961 provides protection of men and machines by enabling and disabling a safety circuit. This is done by the adjusted time delay function. Simply select 1 out of 5 delay functions with a rotary switch – ready. The adjusted time is safe over the complete setting range. The UG 6961 is available for different safety functions. It has safe delayed and instantaneous contacts.
Technical specifications
| Width: | 22,5 mm |
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
| SIL acc. to IEC/EN 62061: | 3 |
| Nominal voltage: | DC |
| Thermal current Ith max.: | 8 A |
| 1- / 2-channel: | 2 |
| Application: | Emergency stop, Light barrier, Safety mat, Safety gate, Two-hand |
| Cross fault detection: | Yes |
| Connection: | Pluggable screw terminals, Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire |
| Safe output contacts, redundant NO contacts: | 2 |
| Approvals: | UL |
| Type: | UG 6961 |
Downloads
- Datasheet UG 6961 (PDF - 4.72 MB)
- EPLAN macro UG 6961 (ZIP - 4.13 MB)
- Product overview SAFEMASTER C (PDF - 485.36 KB)
- Tender text UG 6961 (TXT - 2.05 KB)
Advantages
- Various delay functions adjustable at device:
- Release delay
- Release delay retriggerable
- On delay
- Fleeting on make / break
- Delay function settable via potentiometer - Various safety functions defined:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain - Manual or auto start
- Protection against manipulation by sealable transparent cover
Features
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 - Acc. to EN 50156-1 for furnaces
- Line fault detection on On-button:
- Manual restart or automatic restart
- With or without cross fault monitoring
- 2-channel
- Forcibly guided output contacts
- Output: max. 4 NO instantaneous semiconductor monitoring output
- LED indicator for operation, delay contects and failure
- As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals - Width: 22.5 mm
Other Products from Industrial Safety Controls Inc
DOLD Relay Extension Module LG 5929
If more safety cicuits have to be switched, than a safety module provides, the extension module LG 5929 is used.
Comitronic-BTI RFID Disconnect Lockguard
BY COMITRONIC-BTI Interlocking safety device for rotary disconnect switch, power-on device, hazardous machine safeguard with input/output management by special RFID key control up to 16 million codes. Conformity : ISO 13849-1 2015 EN 62061/A2 2015 EN 60947-5-3 2014 ISO 14119 2013 SIL3 PLe with AWAX26XXL / AWAX SOFT